Ultrasound equipment with two independent channels and three frequencies: 1, 2 and 3 MHz, in both continuous and pulsating mode.
Important note: a specific handpiece is needed in order to use the 2 MHz frequencies.
Our ultrasound equipment has luminous non contact indicator heads that mean you can check the correctness of the transmitting head-tissue contact. They are also self calibrating so they don't have to be adjusted. The SONIC EXCELLENT device can provide ultrasound in continuous or pulsed mode and the duty cycle can be adjusted in different ways.This significantly reduces the diathermic effect as the heat is dispersed in the interval between one pulse and another. In addition pulsed transmission gives the technical advantage of less potential transducer overheating so higher intensities can be used.
Scientific experience has confirmed that the absorption of ultrasound significantly increases the extendibility of connective tissue. This is very important in the treatment of scarred tissue, surfaces, joint capsule surfaces and tendinitis
THERAPEUTIC EFFECTS
The therapeutic effects of ultrasounds are partly due to the increase in temperature. These take the form of analgesia, relaxation of the muscles, and a fibrolytic and trophic effect.
- Analgesia - The analgesic effect is due to the heat, and probably also the direct action of the ultrasounds on the sensitive nerve endings.
- Relaxation of contracted muscles - Relaxation of contracted muscles is associated with the thermal effect and micro massaging of the tissue, induced by the passage of the ultrasounds.
- Fibrolytic effect - Oscillation of the tissue particles, caused by the ultrasounds, results in disruption of the collagen fibers in fibrous and sclerotized tissue.
- Trophic effect - Vasodilation, which results from a rise in temperature, facilitates the removal of catabolites and puts nutritive substances and oxygen into the tissue. In this way ultrasounds improve trophism of the tissue, facilitate repair of tissue damage and speed up resolution of inflammatory processes.
ACCESSORIES SUPPLIED
- 1 Power cable
- 1 Manual / certification
- 2 Fuses
- 2 Handpieces 5cm2 1/3 MHz
- 1 Touchscreen Pen
- 2 Contact sensor with wire
- 1 Smart Card
Product Information
Specifications |
---|
Power supply:230 Vac, 50-60 Hz |
Power supply (on request):115 Vac, 50-60 Hz |
Maximum mains power absorption:70 VA |
LCD display:Graphics 320 x 340 pixel Touchscreen |
Programmable treatment time:up to 30 minutes |
Emission frequency:1 MHz - 2 MHz - 3 MHz |
Duty Cycle adjustable:10% - 100% |
Continuous peak power:2 W / cm2 |
Pulsed peak power:3 W / cm2 |
Electrical insulation class UNI EN 60601-1 standard:II B |
Device class in compliance with the 93/42/CEE directive:I / BF |
Degree of protection against the input of liquids UNI EN 60601-1 standard:IPX0 |
Output channels:2 independents |
Stored protocols:91 |
Storable protocols on the user memory:250 |
Storable protocols on the smart-card:250 |
Table container in plastic , external size (width x height x depth):39 x 13 x 32 cm |
Unit body weight:6.55 Kg |