Sonic 1 - Plus Line

Single output ultrasound therapy equipment, with 1 output, complete with 1/3 MHz multi-frequency handpiece. Display 320x240 px,  treatment time up to 60 minutes, 200 storable protocols. Smart Card included.

 

Our ultrasound equipment has luminous non contact indicator heads that  mean  you can check the correctness of the transmitting head - tissue contact. They are also self calibrating so they don't have to be adjusted. The SONIC series devices can provide ultrasound in continuous or pulsed mode and the duty cycle can be adjusted in different ways. This  significantly  reduces  the  diathermic  effect  as  the  heat  is  dispersed  in  the interval between one pulse and another. In  addition  pulsed  transmission  gives  the  technical  advantage  of  less  potential transducer overheating so higher intensities can be used. 

Scientific experience has confirmed that the absorption of ultrasound significantly increases the extendibility of connective tissue. This is very important in the treatment of scarred tissue, surfaces, joint capsule surfaces and tendinitis.

 

THERAPEUTIC EFFECTS

The therapeutic effects of ultrasounds are partly due to the increase in temperature. These take the form of analgesia, relaxation of the muscles, and a fibrolytic and trophic effect.

  • Analgesia - The analgesic effect is due to the heat, and probably also the direct action of the ultrasounds on the sensitive nerve endings.
  • Relaxation of contracted muscles - Relaxation of contracted muscles is associated with the thermal effect and micro massaging of the tissue, induced by the passage of the ultrasounds.
  • Fibrolytic effect - Oscillation of the tissue particles, caused by the ultrasounds, results in disruption of the collagen fibers in fibrous and sclerotized tissue.
  • Trophic effect - Vasodilation, which results from a rise in temperature, facilitates the removal of catabolites and puts nutritive substances and oxygen into the tissue. In this way ultrasounds improve trophism of the tissue, facilitate repair of tissue damage and speed up resolution of inflammatory processes.

ACCESSORIES SUPPLIED

  • 1 Power cable
  • 1 Manual / certification
  • 2 Fuses
  • 1 Handpiece 5cm2 1/3 MHz
  • 1 Contact sensor with wire
  • 1 Smart Card

Product Information

Specifications
Power supply:230 Vac, 50-60Hz
Power supply:115 Vac, 50-60Hz, upon request
Maximum mains power absorption:40 VA
Backlit LCD display:b/w graphics 320 x 240 pixels
Programmable treatment time:up to 60 minutes
Electrical insulation class UNI EN 60601-1 standard:I / BF
Electrical insulation class UNI EN 60601-1 standard:I / BF
Degree of protection against the input of liquids UNI EN 60601-1 standard:IPX0
Emission frequency:1 MHz and 3 MHz
Duty Cycle adjustable:10% – 100 %
Continuous peak power:2 W/cm2
Pulsed peak power:3 W/cm2
Output channels:1
Stored protocols:60
Storable protocols in the smart-card:200
Storable protocols in the user memory:200
External size (width x height x depth):39 x 13x 32 cm
Weight:4.2 Kg